Two new supraglottic airway devices, the LMA Supreme™ (LMA) and the i-gel™, offer potential benefits when inserted by inexperienced operators. This study compared the insertion success rate and ventilation profile between the LMA Supreme and the i-gel when inserted by operators without previous airway management expertise. Following a short lecture and manikin training, airway novices were randomly allocated to insert either the LMA Supreme or the i-gel into 80 patients undergoing breast surgery. The primary outcome was first-time success rate, and secondary outcomes were overall success rate, insertion time, airway leak pressure, tidal volume during pressure controlled ventilation at 17 cmH 2O, and adverse events. First-time insertion success rate was significantly higher for the LMA Supreme than the i-gel (30/39 (77%) vs 22/41 (54%); p = 0.029). Significantly more placement failures occurred with the i-gel (6 vs 0, p = 0.025). Mean (SD) leak pressure (29 (8) vs 23 (11) cmH 2O, p = 0.007) and expired tidal volume (PCV 17 cmH 2O) (785 (198) vs 654 (91), p = 0.001) were significantly greater with the LMA Supreme than with the i-gel, respectively. More patients complained of pharyngolaryngeal pain with the LMA Supreme than with the i-gel (17/39 (44%) vs 8/41 (20%); p = 0.053). We found better first time success rate, fewer failures, and a better seal with the LMA Supreme compared with the i-gel, indicating that the LMA Supreme may be preferable for emergency airway use by novices. © 2012 The Association of Anaesthetists of Great Britain and Ireland.

LMA Supreme (TM) vs i-gel (TM)- a comparison of insertion success in novices

RAGAZZI, Riccardo;FINESSI, Luca;FARINELLI, Ilaria;ALVISI, Raffaele;VOLTA, Carlo Alberto
2012

Abstract

Two new supraglottic airway devices, the LMA Supreme™ (LMA) and the i-gel™, offer potential benefits when inserted by inexperienced operators. This study compared the insertion success rate and ventilation profile between the LMA Supreme and the i-gel when inserted by operators without previous airway management expertise. Following a short lecture and manikin training, airway novices were randomly allocated to insert either the LMA Supreme or the i-gel into 80 patients undergoing breast surgery. The primary outcome was first-time success rate, and secondary outcomes were overall success rate, insertion time, airway leak pressure, tidal volume during pressure controlled ventilation at 17 cmH 2O, and adverse events. First-time insertion success rate was significantly higher for the LMA Supreme than the i-gel (30/39 (77%) vs 22/41 (54%); p = 0.029). Significantly more placement failures occurred with the i-gel (6 vs 0, p = 0.025). Mean (SD) leak pressure (29 (8) vs 23 (11) cmH 2O, p = 0.007) and expired tidal volume (PCV 17 cmH 2O) (785 (198) vs 654 (91), p = 0.001) were significantly greater with the LMA Supreme than with the i-gel, respectively. More patients complained of pharyngolaryngeal pain with the LMA Supreme than with the i-gel (17/39 (44%) vs 8/41 (20%); p = 0.053). We found better first time success rate, fewer failures, and a better seal with the LMA Supreme compared with the i-gel, indicating that the LMA Supreme may be preferable for emergency airway use by novices. © 2012 The Association of Anaesthetists of Great Britain and Ireland.
2012
Ragazzi, Riccardo; Finessi, Luca; Farinelli, Ilaria; Alvisi, Raffaele; Volta, Carlo Alberto
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1533781
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 36
social impact