Exposure of cells to an external sufficiently strong electric field results in the formation of pores across the membrane. This phenomenon, termed electropermeabilization, permits the transport of poorly permeant molecules into cytosol. In clinical practice, cell membrane permeabilization for drug electrotransfer is achieved using the ESOPE pulse protocol (1000 V/cm, 8 pulses, 100 µs, 5 kHz). The aim of this study was to investigate several combinations of electric field amplitude and pulse number able to induce electropermeabilization as the one observed when the ESOPE protocol was applied. Decreasing electric field amplitudes (1000 to 300 V/cm) in combination with increasing number of pulses (8 to 320) were applied to in vitro MG63 cells. Propidium iodide and Calcein blue AM uptake were used to evaluate cell electropermeabilization and viability. Results showed that the threshold of local electric field needed to obtain electropermeabilization decreased exponentially with increasing the number of pulses delivered (r2=0.92, p<0.0001). The absorbed dose threshold was dependent on the number of pulses for each voltage applied (r2=0.96, p<0.0001). In conclusion, the possibility of applying an increased number of pulses rather than increasing the electric field amplitude to perform electropermeabilization, may become an important tool for electropermeabilization – related clinical applications.

Identification of in Vitro Electropermeabilization Equivalent Pulse Protocols

ONGARO, Alessia
Primo
;
PELLATI, Agnese
Secondo
;
CARUSO, Angelo;DE MATTEI, Monica
Penultimo
;
2011

Abstract

Exposure of cells to an external sufficiently strong electric field results in the formation of pores across the membrane. This phenomenon, termed electropermeabilization, permits the transport of poorly permeant molecules into cytosol. In clinical practice, cell membrane permeabilization for drug electrotransfer is achieved using the ESOPE pulse protocol (1000 V/cm, 8 pulses, 100 µs, 5 kHz). The aim of this study was to investigate several combinations of electric field amplitude and pulse number able to induce electropermeabilization as the one observed when the ESOPE protocol was applied. Decreasing electric field amplitudes (1000 to 300 V/cm) in combination with increasing number of pulses (8 to 320) were applied to in vitro MG63 cells. Propidium iodide and Calcein blue AM uptake were used to evaluate cell electropermeabilization and viability. Results showed that the threshold of local electric field needed to obtain electropermeabilization decreased exponentially with increasing the number of pulses delivered (r2=0.92, p<0.0001). The absorbed dose threshold was dependent on the number of pulses for each voltage applied (r2=0.96, p<0.0001). In conclusion, the possibility of applying an increased number of pulses rather than increasing the electric field amplitude to perform electropermeabilization, may become an important tool for electropermeabilization – related clinical applications.
2011
Ongaro, Alessia; Pellati, Agnese; Caruso, Angelo; M., Battista; F., De Terlizzi; DE MATTEI, Monica; M., Fini
File in questo prodotto:
File Dimensione Formato  
Ongaro A. et al TCRT 2011 .pdf

solo gestori archivio

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.73 MB
Formato Adobe PDF
1.73 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1435714
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 19
social impact