Three-dimensional numerical simulations of the effect of fouling on an axial compressor stage were carried out. As a case study, the NASA Stage 37 was considered for the numerical investigation, which was performed by means of a commercial computational fluid dynamic code. The numerical model was validated against the experimental data available from literature. Computed performance maps and main flow field features showed a good agreement with the experimental data. The model was considered representative of a realistic compressor stage. The model was then used to simulate the occurrence of fouling by imposing different combinations of added thickness and surface roughness levels. The effect of fouling on compressor performances was studied. Reductions in the flow coefficient and in the pressure coefficient were found to be of the same order of magnitude of the experimental results found in literature. The model developed seems to overcome some of the limitations of other models found in literature that tend to significantly underestimate the actual values of performance reduction. The numerical results were also used to analyze and debug the stage performance scaling procedure used in stage-stacking models in order to represent fouling in multistage compressors. The analysis highlighted that scaling can adequately represent the behavior of the fouled stage in the choked flow region, but it does not capture the reduction in the maximum of the pressure coefficient, which is instead revealed by the numerical simulations. Finally, blockage due to fouling was investigated both qualitatively and quantitatively.

Computational Fluid Dynamics Simulation of Fouling on Axial Compressor Stages

MORINI, Mirko;PINELLI, Michele;SPINA, Pier Ruggero;VENTURINI, Mauro
2010

Abstract

Three-dimensional numerical simulations of the effect of fouling on an axial compressor stage were carried out. As a case study, the NASA Stage 37 was considered for the numerical investigation, which was performed by means of a commercial computational fluid dynamic code. The numerical model was validated against the experimental data available from literature. Computed performance maps and main flow field features showed a good agreement with the experimental data. The model was considered representative of a realistic compressor stage. The model was then used to simulate the occurrence of fouling by imposing different combinations of added thickness and surface roughness levels. The effect of fouling on compressor performances was studied. Reductions in the flow coefficient and in the pressure coefficient were found to be of the same order of magnitude of the experimental results found in literature. The model developed seems to overcome some of the limitations of other models found in literature that tend to significantly underestimate the actual values of performance reduction. The numerical results were also used to analyze and debug the stage performance scaling procedure used in stage-stacking models in order to represent fouling in multistage compressors. The analysis highlighted that scaling can adequately represent the behavior of the fouled stage in the choked flow region, but it does not capture the reduction in the maximum of the pressure coefficient, which is instead revealed by the numerical simulations. Finally, blockage due to fouling was investigated both qualitatively and quantitatively.
2010
Morini, Mirko; Pinelli, Michele; Spina, Pier Ruggero; Venturini, Mauro
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1391199
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 70
  • ???jsp.display-item.citation.isi??? 46
social impact