BACKGROUND: Current treatment standards for patients undergoing primary percutaneous coronary intervention support early infusion of abciximab, followed by bare-metal stent (BMS) implantation. Whether the use of sirolimus-eluting stent (SES) would result in a further improvement of clinical outcomes remains to be proven. Similarly, whether tirofiban administered at high-bolus dose (HBD) followed by standard infusion is a valuable alternative to abciximab in the setting of ST-segment elevation myocardial infarction remains uncertain. STUDY DESIGN: Multicentre evaluation of single high-bolus dose tirofiban versus abciximab and sirolimus-eluting versus bare metal stent in acute myocardial infarction (MULTI-STRATEGY) is a phase III, open-label, multinational investigator-driven clinical trial evaluating, with a 2-by-2 factorial design, the safety/efficacy profile of 4 interventional strategies of reperfusion: tirofiban given at HBD (bolus of 25 microg/kg over 3 minutes), followed by an infusion of 0.15 microg/kg per minute for 18 to 24 hours versus abciximab and SES, as compared to BMS implantation in primary percutaneous coronary intervention. The coprimary objectives are (i) the evaluation of the effect of SES versus BMS on the incidence of major adverse cardiac events within 8 months of the index procedure and (ii) the degree of ST-segment resolution obtained after the mechanical intervention for the comparison of HBD tirofiban versus abciximab. The protocol mandates clinical follow-up for 5 years. CONCLUSIONS: MULTI-STRATEGY will evaluate the role of SES and HBD tirofiban versus BMS and abciximab in the acute management of patients presenting with ST-segment elevation myocardial infarction
Two-by-two factorial comparison of high-bolus-dose tirofiban followed by standard infusion versus abciximab and sirolimus-eluting versus bare-metal stent implantation in patients with acute myocardial infarction: design and rationale for the MULTI-STRATEGY trial
Valgimigli M
Primo
;CAMPO, Gianluca Calogero;FERRARI, RobertoPenultimo
;Percoco G.Ultimo
2007
Abstract
BACKGROUND: Current treatment standards for patients undergoing primary percutaneous coronary intervention support early infusion of abciximab, followed by bare-metal stent (BMS) implantation. Whether the use of sirolimus-eluting stent (SES) would result in a further improvement of clinical outcomes remains to be proven. Similarly, whether tirofiban administered at high-bolus dose (HBD) followed by standard infusion is a valuable alternative to abciximab in the setting of ST-segment elevation myocardial infarction remains uncertain. STUDY DESIGN: Multicentre evaluation of single high-bolus dose tirofiban versus abciximab and sirolimus-eluting versus bare metal stent in acute myocardial infarction (MULTI-STRATEGY) is a phase III, open-label, multinational investigator-driven clinical trial evaluating, with a 2-by-2 factorial design, the safety/efficacy profile of 4 interventional strategies of reperfusion: tirofiban given at HBD (bolus of 25 microg/kg over 3 minutes), followed by an infusion of 0.15 microg/kg per minute for 18 to 24 hours versus abciximab and SES, as compared to BMS implantation in primary percutaneous coronary intervention. The coprimary objectives are (i) the evaluation of the effect of SES versus BMS on the incidence of major adverse cardiac events within 8 months of the index procedure and (ii) the degree of ST-segment resolution obtained after the mechanical intervention for the comparison of HBD tirofiban versus abciximab. The protocol mandates clinical follow-up for 5 years. CONCLUSIONS: MULTI-STRATEGY will evaluate the role of SES and HBD tirofiban versus BMS and abciximab in the acute management of patients presenting with ST-segment elevation myocardial infarctionFile | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0002870307002451-main.pdf
solo gestori archivio
Descrizione: versione editoriale
Tipologia:
Full text (versione editoriale)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
164.25 kB
Formato
Adobe PDF
|
164.25 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.