Routine quality control procedures for mammography need a periodical testing of the X ray units. The checks of kV(p) accuracy, mA linearity, exposure reproducibility and HVL consistency require several instruments (non-invasive kV(p) meter, dosemeter, absorbers, etc.) and a lot of time. The use of a new instrument for a quick and easy measurement of kV(p), ripple, HVL, exposure time and incident air kerma is presented. The instrument, composed of an X ray probe and a portable computer, allows the evaluation of the above parameters in a single shot. Two mammographic units have been routinely tested measuring kV(p), HVL, exposure time and incident air kerma. The evaluation has been performed exposing the probe during the execution of a performance phantom radiograph. The relationships between the fluctuations of the measured parameters are compared with the limiting values proposed by CEC guidelines. Correlation analysis of the whole data set allows malfunctioning identification. The ins...

In-field testing of a new instrument for quality control in mammography

GAMBACCINI, Mauro;MARZIANI, Michele;
1995

Abstract

Routine quality control procedures for mammography need a periodical testing of the X ray units. The checks of kV(p) accuracy, mA linearity, exposure reproducibility and HVL consistency require several instruments (non-invasive kV(p) meter, dosemeter, absorbers, etc.) and a lot of time. The use of a new instrument for a quick and easy measurement of kV(p), ripple, HVL, exposure time and incident air kerma is presented. The instrument, composed of an X ray probe and a portable computer, allows the evaluation of the above parameters in a single shot. Two mammographic units have been routinely tested measuring kV(p), HVL, exposure time and incident air kerma. The evaluation has been performed exposing the probe during the execution of a performance phantom radiograph. The relationships between the fluctuations of the measured parameters are compared with the limiting values proposed by CEC guidelines. Correlation analysis of the whole data set allows malfunctioning identification. The ins...
1995
Gambaccini, Mauro; Marziani, Michele; Candini, Gc; Deguglielmo, E; Bertaggia, C.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1203376
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact