The Italian External Quality Assessment scheme for fragile X syndrome started in 2001 as an activity funded by the National Health System and coordinated by the National Institute of Public Health. The aim of this work is to present the data of 5 years (2001--2004 and 2006) of survey. The External Quality Assessment scheme was designed to cover the following points: (a) genotyping and (b) interpretation and reporting of results. Overall, the scheme covered about 65% of all Italian public laboratories. The average reporting of results was 91.6%, with an overall success rate of 76%. The rate of diagnostic errors observed was on average 5%. Inaccuracy in sizing of CGG repeats of normal and premutated alleles was reported. During the survey the proportion of laboratories using a Southern blotting, polymerase chain reaction, and ABI sizing kit in combination rose from 36.8% to 70.6%. The reports from laboratories showed incompleteness and considerable variations in expected outcomes. For this reason, in 2004 a model for written reports was introduced. In conclusion, these data underscore the need to participate in External Quality Assessment schemes as an educational resource to ensure quality in molecular genetic testing.

The Italian External Quality Assessment scheme for fragile x syndrome: the results of a 5-year survey

FERLINI, Alessandra;
2008

Abstract

The Italian External Quality Assessment scheme for fragile X syndrome started in 2001 as an activity funded by the National Health System and coordinated by the National Institute of Public Health. The aim of this work is to present the data of 5 years (2001--2004 and 2006) of survey. The External Quality Assessment scheme was designed to cover the following points: (a) genotyping and (b) interpretation and reporting of results. Overall, the scheme covered about 65% of all Italian public laboratories. The average reporting of results was 91.6%, with an overall success rate of 76%. The rate of diagnostic errors observed was on average 5%. Inaccuracy in sizing of CGG repeats of normal and premutated alleles was reported. During the survey the proportion of laboratories using a Southern blotting, polymerase chain reaction, and ABI sizing kit in combination rose from 36.8% to 70.6%. The reports from laboratories showed incompleteness and considerable variations in expected outcomes. For this reason, in 2004 a model for written reports was introduced. In conclusion, these data underscore the need to participate in External Quality Assessment schemes as an educational resource to ensure quality in molecular genetic testing.
2008
Falbo, V; Floridia, G; Tosto, F; Censi, F; Salvatore, M; Ravani, A; Ferlini, Alessandra; Melis, Ma; Grasso, M; Bricarelli, Fd; Taruscio, D.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/533188
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact