Background: Indeterminate non-calcified lung nodules are frequent when low-dose spiral computed tomography (LD-CT) is used for lung cancer screening. We assessed the diagnostic utility of a non-invasive work-up protocol for nodules detected at baseline in volunteers enrolled in our single-centre screening trial, and followed for at least 1 year. Methods: 5201 high-risk volunteers, recruited over 1 year from October 2004, underwent baseline LD-CT; 4821 (93%) returned for the first repeat LD-CT. Nodules ≤5 mm underwent repeat LD-CT at 1 year; nodules 5.1-8 mm underwent LD-CT 3 months later; lesions >8 mm received combined CT-positron emission tomography (CT-PET). A subset of nodules >8 mm was studied by CT with contrast. Protocol failures were delayed diagnosis with disease progression beyond stage I, and negative surgical biopsy. Results: 2754 (53%) volunteers presented one or more non-calcified nodules. Ninety-two lung cancers were diagnosed: 55 at baseline and 37 at annual screening (66% stage I). Among the 37 incident cancers, 17 had a baseline nodule that remained stage I, 7 had a baseline nodule that progressed beyond stage I, and 13 presented a new malignant nodule. Baseline and annual cancers were 79 (1.5%) and 13 (0.2%), respectively. In 15 of 104 (14%) invasive diagnostic procedures, the lesion was benign. Sensitivity, and specificity were 91 and 99.7%, respectively, for the entire protocol; 88 and 93% for CT-PET; and 100 and 59% for CT with contrast. Conclusions: The protocol limits invasive diagnostic procedures while few patients have diagnosis delay, supporting the feasibility of lung cancer screening in high-risk subjects by LD-CT. Nevertheless further optimization of the clinical management of screening-detected nodules is necessary. © 2008 Elsevier Ireland Ltd. All rights reserved.

Lung cancer screening with low-dose computed tomography: A non-invasive diagnostic protocol for baseline lung nodules

Paganelli, Giovanni;
2008

Abstract

Background: Indeterminate non-calcified lung nodules are frequent when low-dose spiral computed tomography (LD-CT) is used for lung cancer screening. We assessed the diagnostic utility of a non-invasive work-up protocol for nodules detected at baseline in volunteers enrolled in our single-centre screening trial, and followed for at least 1 year. Methods: 5201 high-risk volunteers, recruited over 1 year from October 2004, underwent baseline LD-CT; 4821 (93%) returned for the first repeat LD-CT. Nodules ≤5 mm underwent repeat LD-CT at 1 year; nodules 5.1-8 mm underwent LD-CT 3 months later; lesions >8 mm received combined CT-positron emission tomography (CT-PET). A subset of nodules >8 mm was studied by CT with contrast. Protocol failures were delayed diagnosis with disease progression beyond stage I, and negative surgical biopsy. Results: 2754 (53%) volunteers presented one or more non-calcified nodules. Ninety-two lung cancers were diagnosed: 55 at baseline and 37 at annual screening (66% stage I). Among the 37 incident cancers, 17 had a baseline nodule that remained stage I, 7 had a baseline nodule that progressed beyond stage I, and 13 presented a new malignant nodule. Baseline and annual cancers were 79 (1.5%) and 13 (0.2%), respectively. In 15 of 104 (14%) invasive diagnostic procedures, the lesion was benign. Sensitivity, and specificity were 91 and 99.7%, respectively, for the entire protocol; 88 and 93% for CT-PET; and 100 and 59% for CT with contrast. Conclusions: The protocol limits invasive diagnostic procedures while few patients have diagnosis delay, supporting the feasibility of lung cancer screening in high-risk subjects by LD-CT. Nevertheless further optimization of the clinical management of screening-detected nodules is necessary. © 2008 Elsevier Ireland Ltd. All rights reserved.
2008
Veronesi, Giulia; Bellomi, Massimo; Mulshine, James L.; Pelosi, Giuseppe; Scanagatta, Paolo; Paganelli, Giovanni; Maisonneuve, Patrick; Preda, Lorenzo; Leo, Francesco; Bertolotti, Raffaella; Solli, Piergiorgio; Spaggiari, Lorenzo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2383079
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 45
  • Scopus 155
  • ???jsp.display-item.citation.isi??? 138
social impact