Objectives-The purpose of this study was to compare conventional 2-dimensional (2D) B-mode sonography with 3-dimensional (3D) sonography for assessing gallbladder volume and contractility. Methods-Gallbladder volume and contractility were evaluated in 32 healthy volunteers after fasting and abstinence from smoking for 8 hours and after a standardized balanced liquid meal. The gallbladder was evaluated with 2D sonography (with the use of the ellipsoid method) and with 3D sonography using a volumetric matrix probe. Both measurements were made by an operator who was skilled in sonography and an unskilled operator. The group of volunteers was subdivided into 2 subgroups incluDing 16 participants, which represented the 2 moments of acquisition by the techniques, particularly for the unskilled operator. Results-The postprandial volumes obtained with 3D sonography were significantly lower in comparison to the volumes obtained with 2D sonography (P= .013), and there was a significant difference between the measurements made by the skilled and unskilled operators only for 2D sonography (P< .001), whereas between the 2 moments of acquisition by the 3D technique, there was no significant difference. The reproducibility of the technique for evaluation of gallbladder volumes was higher for 3D sonography than 2D sonography, particularly for the postprandial evaluation. Conclusions-The new 3D sonographic method using a volumetric matrix probe is a simple, reliable, and more reproducible technique than conventional 2D sonography, even if performed by an unskilled operator, and it allows a reliable stimulation test for a gallbladder dynamic study.

A new reliable method for evaluating gallbladder dynamics the 3-dimensional sonographic examination

DE GIORGIO, Roberto;
2016

Abstract

Objectives-The purpose of this study was to compare conventional 2-dimensional (2D) B-mode sonography with 3-dimensional (3D) sonography for assessing gallbladder volume and contractility. Methods-Gallbladder volume and contractility were evaluated in 32 healthy volunteers after fasting and abstinence from smoking for 8 hours and after a standardized balanced liquid meal. The gallbladder was evaluated with 2D sonography (with the use of the ellipsoid method) and with 3D sonography using a volumetric matrix probe. Both measurements were made by an operator who was skilled in sonography and an unskilled operator. The group of volunteers was subdivided into 2 subgroups incluDing 16 participants, which represented the 2 moments of acquisition by the techniques, particularly for the unskilled operator. Results-The postprandial volumes obtained with 3D sonography were significantly lower in comparison to the volumes obtained with 2D sonography (P= .013), and there was a significant difference between the measurements made by the skilled and unskilled operators only for 2D sonography (P< .001), whereas between the 2 moments of acquisition by the 3D technique, there was no significant difference. The reproducibility of the technique for evaluation of gallbladder volumes was higher for 3D sonography than 2D sonography, particularly for the postprandial evaluation. Conclusions-The new 3D sonographic method using a volumetric matrix probe is a simple, reliable, and more reproducible technique than conventional 2D sonography, even if performed by an unskilled operator, and it allows a reliable stimulation test for a gallbladder dynamic study.
2016
Serra, Carla; Pallotti, Francesca; Bortolotti, Mauro; Caputo, Carla; Felicani, Cristina; DE GIORGIO, Roberto; Barbara, Giovanni; Nardi, Elena; Labate Antonio Maria, Morselli
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2374840
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact