The final results of radon monitoring in 438 schools located in the province of Lecce (Puglia Region, South Italy) showed an average radon concentration of 215 ± 20 Bq m(-3) and that 7% of schools exceeded 500 Bq m(-3), the current Italian action level for radon in workplaces, and consequently required remedial actions. The activity described in the present paper includes the main elements of the remediation project in a subgroup of school buildings. The main radon control systems adopted were sub-slab depressurization (in 57% of schools) and the active ventilation of the crawlspace (in 21% of schools). This experience allows us to put in evidence relevant critical aspects, such as the influence of the karstic nature of the area, the optimization of remediation, the architectural constraints in the case of buildings of architectural or historical interest, which are discussion herein. Moreover, considering the new reference level for radon in workplaces introduced by the new EU Basic Safety Standards, a new analysis of data, achieved in the first survey, highlighted that 20% of schools need to be remediated.

Critical aspects of radon remediation in karst limestone areas: some experiences in schools of South Italy

ZANNONI, Giovanni;
2017

Abstract

The final results of radon monitoring in 438 schools located in the province of Lecce (Puglia Region, South Italy) showed an average radon concentration of 215 ± 20 Bq m(-3) and that 7% of schools exceeded 500 Bq m(-3), the current Italian action level for radon in workplaces, and consequently required remedial actions. The activity described in the present paper includes the main elements of the remediation project in a subgroup of school buildings. The main radon control systems adopted were sub-slab depressurization (in 57% of schools) and the active ventilation of the crawlspace (in 21% of schools). This experience allows us to put in evidence relevant critical aspects, such as the influence of the karstic nature of the area, the optimization of remediation, the architectural constraints in the case of buildings of architectural or historical interest, which are discussion herein. Moreover, considering the new reference level for radon in workplaces introduced by the new EU Basic Safety Standards, a new analysis of data, achieved in the first survey, highlighted that 20% of schools need to be remediated.
2017
Tunno, Tiziana; Caricato, Anna Paola; Fernandez, Manuel; Leonardi, Federica; Tonnarini, Sabrina; Veschetti, Miriam; Zannoni, Giovanni; Trevisi, Rosabianca
File in questo prodotto:
File Dimensione Formato  
Tunno_2017_J._Radiol._Prot._37_160 article.pdf

solo gestori archivio

Descrizione: articolo full text
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.06 MB
Formato Adobe PDF
2.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
remedial action school_preprint.pdf

accesso aperto

Descrizione: versione preprint
Tipologia: Pre-print
Licenza: PUBBLICO - Pubblico senza Copyright
Dimensione 1.19 MB
Formato Adobe PDF
1.19 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2367788
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact