An 810-nm diode laser was used to non-surgically treat a 7-mm pocket around an implant that had five threads of bone loss, BoP+, and exudate, and the patient was followed up for 5 years. Non-surgical treatment, home care reinforcement, clinical indices records, and radiographic examination were completed in two consecutive 1-h appointments within 24 h. The patient was monitored frequently for the first 3 months. Subsequently, maintenance debridement visits were scheduled at 3-month intervals. The patient had a decreased probing pocket depth and a negative BoP index compared to initial clinical data, and the results were stable after 1 year. After 5 years of follow-up visits, there appeared to be rebound of the bone level radiographically. Within the limits of this case report, conventional non-surgical periodontal therapy with the adjunctive use of an 810-nm diode laser may be a feasible alternative approach for the management of peri-implantitis. The 5-year clinical and radiographic outcomes indicated maintenance of the clinical improvement.

Non-surgical treatment of peri-implantitis with the adjunctive use of an 810-nm diode laser.

CARINCI, Francesco
2013

Abstract

An 810-nm diode laser was used to non-surgically treat a 7-mm pocket around an implant that had five threads of bone loss, BoP+, and exudate, and the patient was followed up for 5 years. Non-surgical treatment, home care reinforcement, clinical indices records, and radiographic examination were completed in two consecutive 1-h appointments within 24 h. The patient was monitored frequently for the first 3 months. Subsequently, maintenance debridement visits were scheduled at 3-month intervals. The patient had a decreased probing pocket depth and a negative BoP index compared to initial clinical data, and the results were stable after 1 year. After 5 years of follow-up visits, there appeared to be rebound of the bone level radiographically. Within the limits of this case report, conventional non-surgical periodontal therapy with the adjunctive use of an 810-nm diode laser may be a feasible alternative approach for the management of peri-implantitis. The 5-year clinical and radiographic outcomes indicated maintenance of the clinical improvement.
2013
M., Roncati; A., Lucchese; Carinci, Francesco
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2120816
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 54
  • ???jsp.display-item.citation.isi??? ND
social impact