A dynamic method for the preparation of diluted standards in trace analysis by Ion Chromatography is described. The proposed system uses a diffusion cell that through a capillary tube of known dimension, continuously provides large volumes of highly diluted standard. The diffusion cell setting-up and its working conditions are described, and the advantages and difficulties of the dynamic method are pointed out. Loading the cell with concentrated standard solutions (200-10000 ppm), it was possible to produce diluted Na2SO4 standards in the 0.1-10 ppb concentration range. The cell is able to work for nearly a month before the source amount decreased by 1 %. The linearity of the calibration device is good and the method is free of systematic errors. Under strictly controlled experimental condition, the diffusion cell provides primary standards because it allows to obtain concentrations only depending on its geometry.

Dynamic calibration system for trace analysis in ion chromatography

G. BLO
Primo
;
DONDI, Francesco
Secondo
;
1993

Abstract

A dynamic method for the preparation of diluted standards in trace analysis by Ion Chromatography is described. The proposed system uses a diffusion cell that through a capillary tube of known dimension, continuously provides large volumes of highly diluted standard. The diffusion cell setting-up and its working conditions are described, and the advantages and difficulties of the dynamic method are pointed out. Loading the cell with concentrated standard solutions (200-10000 ppm), it was possible to produce diluted Na2SO4 standards in the 0.1-10 ppb concentration range. The cell is able to work for nearly a month before the source amount decreased by 1 %. The linearity of the calibration device is good and the method is free of systematic errors. Under strictly controlled experimental condition, the diffusion cell provides primary standards because it allows to obtain concentrations only depending on its geometry.
1993
Blo, G.; Dondi, Francesco; Balconi, L.; Sigon, F.
File in questo prodotto:
File Dimensione Formato  
Blo1993_Article_DynamicCalibrationSystemForTra.pdf

solo gestori archivio

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 383.96 kB
Formato Adobe PDF
383.96 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1690363
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact