The Authors report their experience with 222 esophagoenteric anastomoses, performed in 211 cases for malignant neoplasms (middle and lower third) of the esophagus or stomach. Particularly, they have performed 4 Sujura operations, 31 esophagogastric, 4 esophagocolic, 183 esophagojejunal anastomoses utilizing SPTU, ILS and EEA circular stapler. GIA was used in the preparation of the stomach before esophagogastroplasty. Mortality rate of the manual period (1970-1980: 114 cases operated) was 14.5% versus 2.2% of the stapling period (1981-1987: 222 cases operated). From the technical point of view reasons of the superiority of stapled technique are discussed and summarized as follows: 1) space not favourable for handsewn anastomoses; 2) stapled technique allows the surgeon to save anastomoses vascularization; 3) the stapler performs the suture simultaneously so to reduce tensile strength on the anastomoses and the fragile esophageal wall especially; 4) stapled agraphes are fixed in three points vs. the two points of the handsewn stitches.

[Technical considerations on 222 cases of esophageal anastomosis using a stapler].

LIBONI, Alberto;ZAMBONI, Paolo;BUCCOLIERO, Francesco;DONINI, Ippolito Giuseppe
1989

Abstract

The Authors report their experience with 222 esophagoenteric anastomoses, performed in 211 cases for malignant neoplasms (middle and lower third) of the esophagus or stomach. Particularly, they have performed 4 Sujura operations, 31 esophagogastric, 4 esophagocolic, 183 esophagojejunal anastomoses utilizing SPTU, ILS and EEA circular stapler. GIA was used in the preparation of the stomach before esophagogastroplasty. Mortality rate of the manual period (1970-1980: 114 cases operated) was 14.5% versus 2.2% of the stapling period (1981-1987: 222 cases operated). From the technical point of view reasons of the superiority of stapled technique are discussed and summarized as follows: 1) space not favourable for handsewn anastomoses; 2) stapled technique allows the surgeon to save anastomoses vascularization; 3) the stapler performs the suture simultaneously so to reduce tensile strength on the anastomoses and the fragile esophageal wall especially; 4) stapled agraphes are fixed in three points vs. the two points of the handsewn stitches.
1989
Liboni, Alberto; Zamboni, Paolo; Mari, C; Uzzau, A; Salomoni, C; Brunelli, G; Buccoliero, Francesco; Donini, Ippolito Giuseppe
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1683985
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact