In Kennedy disease (an X-linked motoneuronal disorder associated with an increase in the number of (CAG)n triplet repeats in the first exon of the Androgen receptor gene; about twice as many as in normal conditions), polymerase chain reaction-amplified genic products exhibit two DNA fragments in the heterozygous female carriers, one with a range between 468 and 495 bp in the normal polymorphic population and a fragment corresponding to the pathological state that reaches 573 bp. These fragments are easily separated by gel-slab electrophoresis and detected by intercalating dye staining (ethidium bromide). As an alternative procedure, capillary zone electrophoresis in polymer networks, consisting of 8% polyacryloylaminoethoxyethanol at 0% cross-linker, offers a simple procedure for separation and on-line detection via UV absorbance at 254 nm, thus avoiding additional staining steps. The capillary column can be repeatedly used for up to 80-100 times and the electropherogram is stored on a magnetic support. Easy comparison among different runs is obtained by aligning all tracings to an internal standard of a 650 bp fragment added as a marker.

Capillary electrophoresis of polymerase chain reaction‐amplified products in polymer networks: The case of Kennedy's disease

FERLINI, Alessandra;
1994

Abstract

In Kennedy disease (an X-linked motoneuronal disorder associated with an increase in the number of (CAG)n triplet repeats in the first exon of the Androgen receptor gene; about twice as many as in normal conditions), polymerase chain reaction-amplified genic products exhibit two DNA fragments in the heterozygous female carriers, one with a range between 468 and 495 bp in the normal polymorphic population and a fragment corresponding to the pathological state that reaches 573 bp. These fragments are easily separated by gel-slab electrophoresis and detected by intercalating dye staining (ethidium bromide). As an alternative procedure, capillary zone electrophoresis in polymer networks, consisting of 8% polyacryloylaminoethoxyethanol at 0% cross-linker, offers a simple procedure for separation and on-line detection via UV absorbance at 254 nm, thus avoiding additional staining steps. The capillary column can be repeatedly used for up to 80-100 times and the electropherogram is stored on a magnetic support. Easy comparison among different runs is obtained by aligning all tracings to an internal standard of a 650 bp fragment added as a marker.
1994
Nesi, M; Righetti, Pg; Patrosso, Mc; Ferlini, Alessandra; Chiari, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1679311
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 29
social impact