Background: Switching platform restorations seems to reduce the peri-implant bone resorption and to preserve the peri-implant soft tissues. Aim: The aim of the present human study was to compare histologically the peri-implant soft tissue in switching and traditional platform implants 4 years after restoration. Materials and Methods: Forty-eight months after implant restoration, 37 peri-implant soft tissue samples from 14 patients were harvested from traditionally restored implants (control group) and from three different platforms mismatching 0.25-0.85 mm (test groups). At the harvesting time, all sites were clinically healthy. Samples were processed to evaluate the inflammatory infiltrate area [inflamed connective tissue (ICT)], the microvascular density (MVD) and the collagen content (AA%). Results: At the analyses, no significant differences were found between groups in terms of ICT, MVD and AA% (p>0.05). In all groups, most samples with a well-preserved junctional epithelium showed a small and localized inflammatory infiltrated associated with not-well-oriented collagen fibres and an increased MVD. Conclusions: Forty-eight months after restoration, switching and traditional platform implants had similar histological peri-implant soft tissue features, despite different bone level changes detected radiographically and published in a previous parent study. The present study seems to confirm platform switching as a safe prosthetic concept leading to better maintenance of peri-implant bone levels. However, further histological studies are required to longitudinally confirm the present data. © 2010 John Wiley & Sons A/S.

Soft tissues around long-term platform switching implant restorations: A histological human evaluation. Preliminary results

TROMBELLI, Leonardo;
2011

Abstract

Background: Switching platform restorations seems to reduce the peri-implant bone resorption and to preserve the peri-implant soft tissues. Aim: The aim of the present human study was to compare histologically the peri-implant soft tissue in switching and traditional platform implants 4 years after restoration. Materials and Methods: Forty-eight months after implant restoration, 37 peri-implant soft tissue samples from 14 patients were harvested from traditionally restored implants (control group) and from three different platforms mismatching 0.25-0.85 mm (test groups). At the harvesting time, all sites were clinically healthy. Samples were processed to evaluate the inflammatory infiltrate area [inflamed connective tissue (ICT)], the microvascular density (MVD) and the collagen content (AA%). Results: At the analyses, no significant differences were found between groups in terms of ICT, MVD and AA% (p>0.05). In all groups, most samples with a well-preserved junctional epithelium showed a small and localized inflammatory infiltrated associated with not-well-oriented collagen fibres and an increased MVD. Conclusions: Forty-eight months after restoration, switching and traditional platform implants had similar histological peri-implant soft tissue features, despite different bone level changes detected radiographically and published in a previous parent study. The present study seems to confirm platform switching as a safe prosthetic concept leading to better maintenance of peri-implant bone levels. However, further histological studies are required to longitudinally confirm the present data. © 2010 John Wiley & Sons A/S.
2011
Canullo, L.; Pellegrini, G.; Allievi, C.; Trombelli, Leonardo; Annibali, S.; Dellavia, C.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1532989
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 59
  • ???jsp.display-item.citation.isi??? 48
social impact