BACKGROUND: The aim of the European Sero-Epidemiology Network (ESEN2) is to harmonise the serological surveillance of vaccine-preventable diseases in Europe. OBJECTIVE: To allow comparison of antibody prevalence in different countries by standardising results into common units. STUDY DESIGN: For varicella zoster virus (VZV), a reference laboratory established a panel of 148 samples, characterised by indirect enzyme-immunoassay (ELISA), indirect immunofluorescence, and complement fixation test. Fifty-seven samples were also studied by the fluorescence antibody to membrane antigen test. The geometric mean of the antibody activity (GMAA) obtained from four ELISA determinations was used to characterise each sample of the panel as positive (GMAA: >100 mIU/ml), equivocal (GMAA: 50-100 mIU/ml) or negative (GMAA: <50 mIU/ml) for antibody to VZV (anti-VZV). Thirteen laboratories, using five different ELISA tests, tested the panel. RESULTS: Agreement with the reference laboratory was above 85% in all cases, and the R(2) values obtained from regression analysis of the quantitative results were always higher than 0.87. Finally, the regression equations could be used to convert national values into a common unitage. CONCLUSION: This study confirmed that results for anti-VZV obtained by different ELISA methods can be converted into common units, enabling the comparison of the seroprevalence profiles obtained in the participant countries.

European Seroepidemiology Network 2: standardisation of assys for seroepidemiology of varicella zoster virus.

GABUTTI, Giovanni;
2006

Abstract

BACKGROUND: The aim of the European Sero-Epidemiology Network (ESEN2) is to harmonise the serological surveillance of vaccine-preventable diseases in Europe. OBJECTIVE: To allow comparison of antibody prevalence in different countries by standardising results into common units. STUDY DESIGN: For varicella zoster virus (VZV), a reference laboratory established a panel of 148 samples, characterised by indirect enzyme-immunoassay (ELISA), indirect immunofluorescence, and complement fixation test. Fifty-seven samples were also studied by the fluorescence antibody to membrane antigen test. The geometric mean of the antibody activity (GMAA) obtained from four ELISA determinations was used to characterise each sample of the panel as positive (GMAA: >100 mIU/ml), equivocal (GMAA: 50-100 mIU/ml) or negative (GMAA: <50 mIU/ml) for antibody to VZV (anti-VZV). Thirteen laboratories, using five different ELISA tests, tested the panel. RESULTS: Agreement with the reference laboratory was above 85% in all cases, and the R(2) values obtained from regression analysis of the quantitative results were always higher than 0.87. Finally, the regression equations could be used to convert national values into a common unitage. CONCLUSION: This study confirmed that results for anti-VZV obtained by different ELISA methods can be converted into common units, enabling the comparison of the seroprevalence profiles obtained in the participant countries.
2006
DE ORY, F; Echevarra, Jm; Kafatos, G; Anastassopoulou, C; Andrews, N; Backhouse, J; Berbers, G; Bruckova, B; Cohen, Di; DE MELKER, H; Davidkin, I; Gabutti, Giovanni; Hesketh, Lm; Johansen, K; Jokinen, S; Jones, L; Linde, A; Miller, E; Mossong, J; Nardone, A; Rota, Mc; Sauerbrei, A; Schneider, F; Smetana, Z; Tischer, A; Tsakris, A; Vranckx, R.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1203052
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 42
  • ???jsp.display-item.citation.isi??? ND
social impact